On this page
Most workplace noise rules are built on an 8-hour average level. In the US, OSHA sets an action level of 85 dBA TWA, which requires a hearing conservation program, and a permissible exposure limit of 90 dBA. NIOSH recommends a stricter 85 dBA limit with a 3 dB exchange rate. In the EU and UK, the action values are 80 and 85 dB(A), and the exposure limit is 87 dB(A) after allowing for hearing protection. Rules vary by country, sector and state. This page is a general summary, not legal advice.
Side-by-side summary
| Rule | First action | Protection mandatory | Limit | Exchange rate |
|---|---|---|---|---|
| OSHA (US, legal) | 85 dBA TWA action level | 90 dBA TWA (85 dBA if a hearing shift is found) | 90 dBA TWA PEL; 140 dB peak | 5 dB |
| NIOSH (US, recommended) | 85 dBA TWA | 85 dBA TWA | 85 dBA TWA REL; 140 dBA ceiling | 3 dB |
| EU Directive 2003/10/EC | 80 dB(A); 135 dB(C) peak | 85 dB(A); 137 dB(C) peak | 87 dB(A); 140 dB(C) peak, at the ear | 3 dB |
| UK Noise at Work Regs 2005 | 80 dB(A); 135 dB(C) peak | 85 dB(A); 137 dB(C) peak | 87 dB(A); 140 dB(C) peak, at the ear | 3 dB |
The EU and UK values use the daily personal noise exposure, LEX,8h, which is an energy average normalised to 8 hours. Where exposure varies a lot from day to day, a weekly average can be used instead.
United States: OSHA
OSHA’s general industry noise standard is 29 CFR 1910.95. Construction has its own standard, 29 CFR 1926.52, with the same 90 dBA limit but less detailed program requirements. Some states run their own OSHA-approved plans.
Action level: 85 dBA TWA
When any worker’s 8-hour TWA reaches 85 dBA (a 50% dose), the employer must run a hearing conservation program. That includes:
- Noise monitoring to find out who is exposed, repeated when equipment or processes change.
- Audiometric testing: a baseline hearing test, then a test every year, to catch hearing changes early.
- Hearing protectors made available at no cost, with a choice of types.
- Training every year on the effects of noise and how to use protection.
- Record keeping of exposure measurements and hearing tests.
PEL: 90 dBA TWA
Above 90 dBA TWA, employers must use feasible engineering or administrative controls to reduce exposure, and workers must wear hearing protection. Protection is also required from 85 dBA for any worker whose hearing test shows a standard threshold shift. Continuous noise should not exceed 115 dBA, and impulse noise should not exceed 140 dB peak.
United States: NIOSH
NIOSH is the federal research agency for workplace health. Its recommended exposure limit of 85 dBA for 8 hours with a 3 dB exchange rate is not legally binding, but it is widely seen as the better guide to protecting hearing. The difference matters at higher levels: at 100 dBA, OSHA permits 2 hours, NIOSH 15 minutes. The guide safe noise exposure times has the full comparison.
European Union: Directive 2003/10/EC
The EU noise directive sets three tiers. Member states write them into national law and may set stricter rules.
| Tier | Daily exposure | Peak | What it means |
|---|---|---|---|
| Lower exposure action value | 80 dB(A) | 135 dB(C) | Assess risk, give information and training, make hearing protection available, offer hearing checks where there is a risk |
| Upper exposure action value | 85 dB(A) | 137 dB(C) | Hearing protection must be worn. Run a programme to reduce noise. Mark and restrict access to loud areas. Workers are entitled to hearing checks |
| Exposure limit value | 87 dB(A) | 140 dB(C) | Must never be exceeded at the worker’s ear, taking hearing protection into account |
The action values ignore hearing protection; the limit value accounts for it. So a worker in 95 dB(A) noise can be within the limit only if their protection reliably brings the level at the ear below 87 dB(A). Hearing protection ratings explains how to estimate that.
United Kingdom: Control of Noise at Work Regulations 2005
The UK regulations implement the EU directive and use the same numbers: 80 and 85 dB(A) action values, 135 and 137 dB(C) peaks, and an 87 dB(A) / 140 dB(C) limit at the ear. They still apply after Brexit. Employers must assess the risk, eliminate or reduce noise where reasonably practicable, provide protection and information, and provide health surveillance (hearing checks) for workers likely to be at risk. They also cover the music and entertainment sectors, which have specific guidance.
Other countries
Many other countries use an 8-hour limit of 85 dB(A) with a 3 dB exchange rate and a 140 dB(C) peak, but details differ, including whether the limit allows for hearing protection. In Canada, for example, each province and the federal government set their own rules. Check your national or state workplace safety regulator for the rules that apply to you.
Screening with a phone
A phone can tell you whether noise is worth a closer look. It can’t tell you whether a workplace complies.
- Open the online sound meter and set it to A-weighting.
- Hold the phone at about ear height where you normally work, with nothing covering the microphone. Don’t point it at a wall or hold it against your body.
- Record each typical task for a few minutes and note the average (Leq), not the maximum.
- Estimate your daily exposure with the noise exposure calculator. The maths is explained in noise dose and TWA.
Treat the result as a range. A calibrated phone is typically within a few dB of a proper meter, and less accurate above about 100 dB. Impact and peak levels are well beyond what a phone can measure reliably. See how to measure noise with your phone for tips.
When you need a proper survey
A formal noise assessment is needed when:
- Screening suggests levels near or above 80 dB(A) (EU/UK) or 85 dBA (US).
- You need to decide who joins a hearing conservation program, which areas need signs, or which protection to buy.
- There is impact or impulse noise, such as presses, nail guns or firearms.
- Equipment, layout or shift patterns change.
- A worker reports tinnitus or a hearing test shows a change.
- The result could be used in a dispute, inspection or claim.
A survey should be done by a competent person using a sound level meter or personal noise dosimeter meeting the relevant standards (IEC 61672 for sound level meters, IEC 61252 for dosimeters), calibrated before and after use. Personal dosimetry, with the meter worn on the shoulder through a full shift, gives the most realistic exposure for workers who move around.
Frequently asked questions
What is the legal noise limit at work in the US?
The OSHA permissible exposure limit is 90 dBA as an 8-hour time-weighted average, with a 5 dB exchange rate. At an 85 dBA TWA, employers must run a hearing conservation program.
What is the noise limit at work in the UK?
Under the Control of Noise at Work Regulations 2005, the exposure limit value is 87 dB(A) daily or weekly exposure and 140 dB(C) peak, taking hearing protection into account. Action is required from 80 dB(A), and protection is mandatory from 85 dB(A).
Can I use a phone app to check noise at work?
For a first screening, yes. A phone reading near or above 80 dBA is a good reason to ask for a proper assessment. It isn’t accurate enough to prove compliance or non-compliance; that needs a calibrated sound level meter or dosimeter.
How do I know if my workplace is too loud without a meter?
A common rule of thumb: if you have to raise your voice to talk to someone about 1 to 2 metres away for part of the day, the noise is probably at or above about 80 to 85 dBA and should be assessed.