How Loud Is This?
Health

Noise dose and TWA explained

Noise dose is the share of your daily noise allowance you have used, as a percentage. 100% means you reached the limit. The TWA turns that dose back into a single 8-hour average level in dBA.

Updated · 4 min read

On this page

To calculate noise dose, split your day into periods at roughly steady levels. For each period, divide the time you spent (C) by the time allowed at that level (T), and add the fractions: D = 100 × Σ(C ÷ T). A dose of 100% means you hit the daily limit. The time-weighted average (TWA) is the steady 8-hour level that would give the same dose.

The dose formula

D = 100 × (C1/T1 + C2/T2 + … + Cn/Tn)

  • C is the time you actually spent at a given level, in hours.
  • T is the allowed time at that level, in hours.

The allowed time comes from the rule you are using:

T = 8 ÷ 2^((L − criterion) ÷ exchange rate)

RuleCriterion levelExchange rateUsual threshold
NIOSH REL85 dBA3 dB80 dBA
OSHA PEL90 dBA5 dB90 dBA
OSHA action level (hearing conservation)90 dBA criterion, 85 dBA trigger5 dB80 dBA

The threshold is the level below which noise is ignored. Under NIOSH and the OSHA action-level rules, anything under 80 dBA counts as zero. The full list of allowed times at each level is in safe noise exposure times.

From dose to TWA

Once you have a dose, convert it to an 8-hour average level:

  • NIOSH: TWA = 10 × log10(D ÷ 100) + 85
  • OSHA: TWA = 16.61 × log10(D ÷ 100) + 90

The 16.61 is 5 ÷ log10(2), which comes from the 5 dB exchange rate. Some reference points:

DoseNIOSH TWAOSHA TWA
25%79 dBA80 dBA
50%82 dBA85 dBA
100%85 dBA90 dBA
200%88 dBA95 dBA
400%91 dBA100 dBA

Going the other way, NIOSH dose is 100 × 2^((TWA − 85) ÷ 3).

Worked example: a mixed day

Say a workday looks like this, with levels measured as averages (Leq) for each task:

TaskLevelTime (C)NIOSH allowed (T)NIOSH C/T
General workshop82 dBA4 h16 h0.25
Running a planer88 dBA2 h4 h0.50
Angle grinder94 dBA0.5 h1 h0.50
Office and breaks70 dBA1.5 hbelow threshold0

NIOSH dose = 100 × (0.25 + 0.50 + 0.50) = 125%. TWA = 10 × log10(1.25) + 85 = about 86 dBA. That is over the recommended limit, even though only 30 minutes of the day was “really loud”.

Same day under OSHA (action-level settings): the allowed times are 24.3 h at 82 dBA, 10.6 h at 88 dBA and 4.6 h at 94 dBA. The dose is 100 × (4/24.3 + 2/10.6 + 0.5/4.6) ≈ 46%, a TWA of about 84 dBA, just under the 85 dBA action level. One day, two answers. That gap is why NIOSH’s numbers are the better guide for protecting hearing.

Projected 8-hour dose

Dosimeters often run for only part of a shift. To estimate the full day, they report a projected dose:

Projected dose = measured dose × (8 ÷ hours measured)

If a 4-hour sample shows 60%, the projected 8-hour dose is 60 × 8 ÷ 4 = 120% (a NIOSH TWA of about 86 dBA). This assumes the unmeasured hours look like the measured ones. If the loud tasks all happened while the meter was running, projection overstates the day. If they happen later, it understates it. When the shift is longer than 8 hours, use the full shift time and don’t project down: a 10-hour shift at 85 dBA is a 125% dose.

TWA, Leq and the 3 dB rule

With a 3 dB exchange rate, TWA is just the Leq spread over 8 hours: TWA = Leq + 10 × log10(hours ÷ 8). So 4 hours at a Leq of 88 dBA gives a TWA of 85 dBA, and 2 hours at 91 dBA gives the same. This is also how the EU and UK daily exposure value, LEX,8h, works. The OSHA 5 dB rule doesn’t follow sound energy, so its TWA can’t be read straight from an Leq when levels vary.

Common mistakes

  • Averaging decibels like ordinary numbers. An hour at 80 dBA and an hour at 100 dBA don’t average to 90 dBA. The loud hour dominates. Work in dose, or energy, and convert back. See how decibels add up.
  • Using peak or maximum readings. Dose uses the average level over each period (Leq). A meter’s maximum reading overstates the dose; a quick glance in a quiet moment understates it.
  • Mixing rules. NIOSH and OSHA doses use different criterion levels and exchange rates. Don’t take allowed times from one rule and the TWA formula from the other.
  • Forgetting the commute and evening. Loud music, power tools or a motorbike after work add to the same day’s dose.

Estimating your own dose

  1. List the activities in your day and roughly how long each lasts.
  2. Measure each one with the online sound meter for a few minutes and note the Leq, holding the device near where your ears would be.
  3. Enter the levels and times in the noise exposure calculator, which does the sum and the TWA for you.
  4. Remember that a phone reading is an estimate, typically within a few dB once calibrated and less accurate above about 100 dB. A 3 dB error doubles or halves the dose, so round up.

This gives a useful screening figure. It doesn’t replace a workplace survey with a dosimeter. See workplace noise limits for when a proper survey is needed.

Frequently asked questions

What does a 100% noise dose mean?

It means you have reached the daily limit: the same as 8 hours at the criterion level (85 dBA for NIOSH, 90 dBA for the OSHA PEL). 50% is half the allowance; 200% is twice the limit.

What TWA is a 50% dose?

Under OSHA’s formula a 50% dose is a TWA of 85 dBA, which is the OSHA action level for a hearing conservation program. Under NIOSH’s formula a 50% dose is about 82 dBA.

Is TWA the same as Leq?

Not quite. Leq is the energy average over the time you measured. A NIOSH-style TWA is the Leq normalised to an 8-hour day, so a 4-hour Leq of 88 dBA becomes a TWA of 85 dBA. OSHA’s TWA uses a 5 dB exchange rate, so it differs from Leq whenever levels vary.

Can I calculate noise dose with my phone?

You can estimate it. Measure the average level of each activity with a sound meter, note how long you spend on each, and add up the shares. Treat the result as a screening estimate, not a compliance measurement.